<entry xmlns="http://pdbe.org/empiar" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="https://ftp.ebi.ac.uk/pub/databases/emtest/empiar/schema/empiar.xsd" accessionCode="EMPIAR-11055" public="true">
    <admin>
        <currentStatus>REL</currentStatus>
        <keyDates>
            <depositionDate>2022-05-09</depositionDate>
            <releaseDate>2022-06-01</releaseDate>
            <updateDate>2022-06-01</updateDate>
        </keyDates>
        <title>Crosshair, semi-automated targeting for electron microscopy with a motorised ultramicrotome</title>
        <correspondingAuthor>
            <authorORCID>0000-0003-4939-4170</authorORCID>
            <firstName>Kimberly</firstName>
            <lastName>Meechan</lastName>
            <organization type="academic">European Molecular Biology Laboratory, Heidelberg, Germany</organization>
            <street>Meyerhofstraße 1</street>
            <townOrCity>Heidelberg</townOrCity>
            <stateOrProvince>Baden-Württemberg</stateOrProvince>
            <country>Germany</country>
            <postOrZipCode>69117</postOrZipCode>
        </correspondingAuthor>
        <principalInvestigator>
            <authorORCID>0000-0001-8027-1836</authorORCID>
            <firstName>Yannick</firstName>
            <lastName>Schwab</lastName>
            <organization type="academic">European Molecular Biology Laboratory, Heidelberg, Germany</organization>
            <street>Meyerhofstraße 1</street>
            <townOrCity>Heidelberg</townOrCity>
            <stateOrProvince>Baden-Württemberg</stateOrProvince>
            <country>Germany</country>
            <postOrZipCode>69117</postOrZipCode>
        </principalInvestigator>
        <principalInvestigator>
            <authorORCID>0000-0003-0260-613X</authorORCID>
            <firstName>Lucy</firstName>
            <lastName>Collinson</lastName>
            <organization type="academic">Francis Crick Institute, London, UK</organization>
            <street>1 Midland Road</street>
            <townOrCity>London</townOrCity>
            <stateOrProvince>Greater London</stateOrProvince>
            <country>United Kingdom</country>
            <postOrZipCode>NW1 1AT</postOrZipCode>
        </principalInvestigator>
        <authorsList>
            <author authorORCID="0000-0003-4939-4170">Meechan K</author>
            <author>Guan W</author>
            <author>Riedinger A</author>
            <author>Stankova V</author>
            <author>Yoshimura A</author>
            <author>Pipitone R</author>
            <author>Milberger A</author>
            <author>Schaar H</author>
            <author authorORCID="0000-0002-9073-9612">Romero-Brey I</author>
            <author>Templin R</author>
            <author authorORCID="0000-0002-8329-5419">Peddie C J</author>
            <author authorORCID="0000-0002-3212-5057">Schieber N L</author>
            <author authorORCID="0000-0003-0994-5652">Jones M L</author>
            <author authorORCID="0000-0003-0260-613X">Collinson L</author>
            <author authorORCID="0000-0001-8027-1836">Schwab Y</author>
        </authorsList>
        <datasetSize>151.0</datasetSize>
        <entryDOI>10.6019/EMPIAR-11055</entryDOI>
        <experimentType>Hard X-ray/X-ray microCT</experimentType>
    </admin>
    <crossReferences>
        <citationList>
            <universalCitation>
                <journalCitation published="true" preprint="true">
                    <author authorORCID="0000-0003-4939-4170" order="1">Meechan K</author>
                    <author order="2">Guan W</author>
                    <author order="3">Riedinger A</author>
                    <author order="4">Stankova V</author>
                    <author order="5">Yoshimura A</author>
                    <author order="6">Pipitone R</author>
                    <author order="7">Milberger A</author>
                    <author order="8">Schaar H</author>
                    <author authorORCID="0000-0002-9073-9612" order="9">Romero-Brey I</author>
                    <author order="10">Templin R</author>
                    <author authorORCID="0000-0002-8329-5419" order="11">Peddie C J</author>
                    <author authorORCID="0000-0002-3212-5057" order="12">Schieber N L</author>
                    <author authorORCID="0000-0003-0994-5652" order="13">Jones M L</author>
                    <author authorORCID="0000-0003-0260-613X" order="14">Collinson L</author>
                    <author authorORCID="0000-0001-8027-1836" order="15">Schwab Y</author>
                    <title>Crosshair, semi-automated targeting for electron microscopy with a motorised ultramicrotome</title>
                    <journal>BioRxiv</journal>
                    <journalAbbreviation>BioRxiv</journalAbbreviation>
                    <country></country>
                    <year>2022</year>
                    <language>English</language>
                </journalCitation>
            </universalCitation>
        </citationList>
    </crossReferences>
    <imageSet>
        <name>sample_a_before_targeting.tif</name>
        <directory>/data/sample_a_e2</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>479</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>1000</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>660</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample a before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_a_after_targeting.tif</name>
        <directory>/data/sample_a_e2</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>465</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>738</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>870</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample a after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample a micro-CT - before reconstruction and before targeting</name>
        <directory>/data/sample_a_e2/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>939</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample a micro-CT (before reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample a micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_a_e2/raw_images/before_targeting/Platy-A_1micron_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>479</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample a micro-CT (after reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample a micro-CT - before reconstruction and after targeting</name>
        <directory>/data/sample_a_e2/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample a micro-CT (before reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample a micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_a_e2/raw_images/after_targeting/2_1um_again_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>465</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample a micro-CT (after reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_b_before_targeting.tif</name>
        <directory>/data/sample_b_e4</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>441</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>1046</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>688</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample b before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_b_after_targeting.tif</name>
        <directory>/data/sample_b_e4</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>559</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>1224</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>774</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample b after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample b micro-CT - before reconstruction and before targeting</name>
        <directory>/data/sample_b_e4/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample b micro-CT (before reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample b micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_b_e4/raw_images/before_targeting/Sample_4_1um_Platy_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>441</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample b micro-CT (after reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample b micro-CT - before reconstruction and after targeting</name>
        <directory>/data/sample_b_e4/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample b micro-CT (before reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample b micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_b_e4/raw_images/after_targeting/4_1um_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>559</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample b micro-CT (after reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_c_before_targeting.tif</name>
        <directory>/data/sample_c_e6</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>462</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>838</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>568</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample c before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_c_after_targeting.tif</name>
        <directory>/data/sample_c_e6</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>430</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>663</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>867</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample c after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample c micro-CT - before reconstruction and before targeting</name>
        <directory>/data/sample_c_e6/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample c micro-CT (before reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample c micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_c_e6/raw_images/before_targeting/Sample_6_1um_Platy_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>462</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample c micro-CT (after reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample c micro-CT - before reconstruction and after targeting</name>
        <directory>/data/sample_c_e6/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample c micro-CT (before reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample c micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_c_e6/raw_images/after_targeting/6_1um_again_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>430</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample c micro-CT (after reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_d_before_targeting.tif</name>
        <directory>/data/sample_d_e9</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>414</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>894</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>576</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample d before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_d_after_targeting.tif</name>
        <directory>/data/sample_d_e9</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>459</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>939</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>762</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample d after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample d micro-CT - before reconstruction and before targeting</name>
        <directory>/data/sample_d_e9/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample d micro-CT (before reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample d micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_d_e9/raw_images/before_targeting/ESample_9_1um_Platy_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>519</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample d micro-CT (after reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample d micro-CT - before reconstruction and after targeting</name>
        <directory>/data/sample_d_e9/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample d micro-CT (before reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample d micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_d_e9/raw_images/after_targeting/9_1um_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>459</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample d micro-CT (after reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_e_before_targeting.tif</name>
        <directory>/data/sample_e_e13</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>415</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>770</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>706</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample e before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_e_after_targeting.tif</name>
        <directory>/data/sample_e_e13</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>443</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>807</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>846</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample e after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample e micro-CT - before reconstruction and before targeting</name>
        <directory>/data/sample_e_e13/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>939</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample e micro-CT (before reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample e micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_e_e13/raw_images/before_targeting/Platy_sample_13_1um_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>463</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample e micro-CT (after reconstruction and before targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample e micro-CT - before reconstruction and after targeting</name>
        <directory>/data/sample_e_e13/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1799</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1344</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample e micro-CT (before reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample e micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_e_e13/raw_images/after_targeting/12_1um_Rec</directory>
        <category>reconstructed volumes</category>
        <headerFormat>PNG</headerFormat>
        <dataFormat>PNG</dataFormat>
        <numImagesOrTiltSeries>443</numImagesOrTiltSeries>
        <framesPerImage>1</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>2016</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>2016</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample e micro-CT (after reconstruction and after targeting) from Bruker Skyscan 1272, along with log files of scan settings</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_f_before_targeting.tif</name>
        <directory>/data/sample_f_c5</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>994</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample f before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_f_after_targeting.tif</name>
        <directory>/data/sample_f_c5</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>993</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample f after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample f micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_f_c5/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>994</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample f micro-CT (after reconstruction and before targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample f micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_f_c5/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>993</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample f micro-CT (after reconstruction and after targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_g_before_targeting.tif</name>
        <directory>/data/sample_g_c8</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>995</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>992</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample g before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_g_after_targeting.tif</name>
        <directory>/data/sample_g_c8</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>993</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>1015</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>987</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample g after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample g micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_g_c8/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>995</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>992</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample g micro-CT (after reconstruction and before targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample g micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_g_c8/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>993</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>987</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample g micro-CT (after reconstruction and after targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_h_before_targeting.tif</name>
        <directory>/data/sample_h_c10</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>996</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>992</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample h before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_h_after_targeting.tif</name>
        <directory>/data/sample_h_c10</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>996</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>991</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample h after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample h micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_h_c10/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>996</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>992</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample h micro-CT (after reconstruction and before targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample h micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_h_c10/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>996</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>991</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample h micro-CT (after reconstruction and after targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_i_before_targeting.tif</name>
        <directory>/data/sample_i_c12</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>995</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>992</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample i before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_i_after_targeting.tif</name>
        <directory>/data/sample_i_c12</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>1015</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>991</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample i after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample i micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_i_c12/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>995</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>992</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample i micro-CT (after reconstruction and before targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample i micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_i_c12/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>991</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample i micro-CT (after reconstruction and after targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_j_before_targeting.tif</name>
        <directory>/data/sample_j_c13</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>993</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample j before targeting (ready for crosshair)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>sample_j_after_targeting.tif</name>
        <directory>/data/sample_j_c13</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>996</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>1015</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>986</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Micro-CT of sample j after targeting (ready for accuracy measures)</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample j micro-CT - after reconstruction and before targeting</name>
        <directory>/data/sample_j_c13/raw_images/before_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>997</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>993</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample j micro-CT (after reconstruction and before targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Raw sample j micro-CT - after reconstruction and after targeting</name>
        <directory>/data/sample_j_c13/raw_images/after_targeting</directory>
        <category>reconstructed volumes</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>1</numImagesOrTiltSeries>
        <framesPerImage>996</framesPerImage>
        <voxelType>UNSIGNED 16 BIT INTEGER</voxelType>
        <dimensions>
            <imageWidth>986</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>1015</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>Raw sample j micro-CT (after reconstruction and after targeting) from Versa 510 X-ray microscope (Zeiss). The corresponding before reconstruction file (.txrm) is available in the same directory.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
</entry>
