<entry xmlns="http://pdbe.org/empiar" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="https://ftp.ebi.ac.uk/pub/databases/emtest/empiar/schema/empiar.xsd" accessionCode="EMPIAR-12081" schemaVersion="0.65" public="true">
    <admin>
        <currentStatus>REL</currentStatus>
        <keyDates>
            <depositionDate>2023-05-10</depositionDate>
            <releaseDate>2026-03-30</releaseDate>
            <updateDate>2026-03-30</updateDate>
        </keyDates>
        <title>Movies of PARP1-DNA Complexes</title>
        <correspondingAuthor private="true">
            <authorORCID>0000-0003-1405-925X</authorORCID>
            <firstName>Aleksandr</firstName>
            <lastName>Sverzhinsky</lastName>
            <organization type="academic">Department of Biochemistry and Molecular Medicine, Universite de Montreal</organization>
            <street>2900 Edouard Montpetit Blvd</street>
            <townOrCity>Montreal</townOrCity>
            <stateOrProvince>Quebec</stateOrProvince>
            <country>Canada</country>
            <postOrZipCode>H3T 1J4</postOrZipCode>
        </correspondingAuthor>
        <principalInvestigator private="true">
            <authorORCID>0000-0002-2714-4317</authorORCID>
            <firstName>John</firstName>
            <middleName>M</middleName>
            <lastName>Pascal</lastName>
            <organization type="academic">Department of Biochemistry and Molecular Medicine, Universite de Montreal</organization>
            <street>2900 Edouard Montpetit Blvd</street>
            <townOrCity>Montreal</townOrCity>
            <stateOrProvince>Quebec</stateOrProvince>
            <country>Canada</country>
            <postOrZipCode>H3T 1J4</postOrZipCode>
        </principalInvestigator>
        <authorsList>
            <author authorORCID="0000-0003-1405-925X">Sverzhinsky A</author>
            <author authorORCID="0000-0002-2714-4317">Pascal JM</author>
        </authorsList>
        <grantSupport>
            <grantReference>
                <fundingBody></fundingBody>
                <code></code>
                <country></country>
            </grantReference>
        </grantSupport>
        <datasetSize units="TB">27.2</datasetSize>
        <entryDOI>10.6019/EMPIAR-12081</entryDOI>
        <experimentType>EMDB</experimentType>
        <scale>molecule</scale>
    </admin>
    <crossReferences>
        <relatedEMDBEntries>
            <emdbEntry>EMD-48285</emdbEntry>
            <emdbEntry>EMD-48313</emdbEntry>
        </relatedEMDBEntries>
        <citationList>
            <universalCitation>
                <journalCitation published="true" preprint="false">
                    <author authorORCID="0000-0003-1405-925X" order="1">Sverzhinsky A</author>
                    <author order="2">Xue H</author>
                    <author authorORCID="0000-0001-9815-1840" order="3">Langelier MF</author>
                    <author order="4">Muniz Corrêa MV</author>
                    <author order="5">Del Mundo J</author>
                    <author authorORCID="0000-0002-5500-9104" order="6">Classen S</author>
                    <author authorORCID="0000-0002-5610-9289" order="7">Hammel M</author>
                    <author authorORCID="0000-0002-1382-1380" order="8">Rothenberg E</author>
                    <author authorORCID="0000-0002-2714-4317" order="9">Pascal JM</author>
                    <title>PARP1-HPF1 structure and dynamics on nicked DNA suggest a mechanism for acute and localized ADP-ribosylation</title>
                    <journal>Nature communications</journal>
                    <journalAbbreviation>Nat Commun</journalAbbreviation>
                    <country></country>
                    <issue>1</issue>
                    <volume>17</volume>
                    <year>2026</year>
                    <language>English</language>
                    <externalReferences type="doi">10.1038/s41467-026-69375-3</externalReferences>
                    <externalReferences type="pubmed">41698892</externalReferences>
                </journalCitation>
            </universalCitation>
        </citationList>
    </crossReferences>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47 on graphene by vitrobot</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>24130</numImagesOrTiltSeries>
        <framesPerImage>40</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>1.069</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>1.069</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Titan Krios) at a nominal pixel resolution of 1.069 A/pix using a Gatan K3 direct electron detector in counting mode. Movies were collected using Leginon (Suloway et al., 2005) at a dose rate of 26.38 e-/Å^2/s with a total electron dose of 52.77 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47-HPF1-Timeless on graphene by vitrobot</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>EER</headerFormat>
        <dataFormat>EER</dataFormat>
        <numImagesOrTiltSeries>9643</numImagesOrTiltSeries>
        <framesPerImage>60</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>4096</imageWidth>
            <pixelWidth>0.751</pixelWidth>
            <imageHeight>4096</imageHeight>
            <pixelHeight>0.751</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Titan Krios) at a nominal pixel resolution of 0.7511 A/pix using a Falcon 4EC direct electron detector (Thermo Fisher Scientific) in counting mode. Movies were collected using Leginon (Suloway et al., 2005) at a dose rate of 7.18 e-/Å^2/s with a total electron dose of 43.08 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47-HPF1-Timeless (crosslinked) on graphene by vitrobot</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>8600</numImagesOrTiltSeries>
        <framesPerImage>40</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>1.0691</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>1.0691</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Titan Krios) at a nominal pixel resolution of 1.069 A/pix using a Gatan K3 direct electron detector in counting mode. Movies were collected using Leginon (Suloway et al., 2005) at a dose rate of 26.38 e-/Å^2/s with a total electron dose of 52.77 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47-HPF1-Timeless (crosslinked) on graphene by vitrobot; tilted collection</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>15299</numImagesOrTiltSeries>
        <framesPerImage>40</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>1.069</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>1.069</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Titan Krios) at a nominal pixel resolution of 1.069 A/pix using a Gatan K3 direct electron detector (Thermo Fisher Scientific) in counting mode at a tilt of 30 degrees. Movies were collected using Leginon (Suloway et al., 2005) at a dose rate of 26.2 e-/Å^2/s with a total electron dose of 83.82 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47-HPF1-Timeless on graphene by Chameleon; grid1</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>EER</headerFormat>
        <dataFormat>EER</dataFormat>
        <numImagesOrTiltSeries>9643</numImagesOrTiltSeries>
        <framesPerImage>60</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>4096</imageWidth>
            <pixelWidth>0.7511</pixelWidth>
            <imageHeight>4096</imageHeight>
            <pixelHeight>0.7511</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Titan Krios) at a nominal pixel resolution of 0.7511 A/pix using a Falcon 4EC direct electron detector (Thermo Fisher Scientific) in counting mode. Movies were collected using Leginon (Suloway et al., 2005) at a dose rate of 7.47 e-/Å^2/s with a total electron dose of 44.81 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47-HPF1-Timeless on graphene by Chameleon; grid2</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>EER</headerFormat>
        <dataFormat>EER</dataFormat>
        <numImagesOrTiltSeries>7445</numImagesOrTiltSeries>
        <framesPerImage>70</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>4096</imageWidth>
            <pixelWidth>0.7511</pixelWidth>
            <imageHeight>4096</imageHeight>
            <pixelHeight>0.7511</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Titan Krios) at a nominal pixel resolution of 0.7511 A/pix using a Falcon 4EC direct electron detector (Thermo Fisher Scientific) in counting mode. Movies were collected using Leginon (Suloway et al., 2005) at a dose rate of 7.90 e-/Å^2/s with a total electron dose of 55.27 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>Unaligned multi-frame micrographs of PARP1-DNA-EB47-HPF1-Timeless in open-hole by Chameleon</name>
        <directory>/data/frames_PARP1-DNA-HPF1-Tmls-EB47_550ms</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>4246</numImagesOrTiltSeries>
        <framesPerImage>40</framesPerImage>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>11520</imageWidth>
            <pixelWidth>0.548</pixelWidth>
            <imageHeight>8184</imageHeight>
            <pixelHeight>0.548</pixelHeight>
        </dimensions>
        <details>The movies were imaged (Talos Arctica) at a nominal pixel resolution of 0.548 A/pix using a K2 Summit direct electron detector (Gatan) in counting mode. Movies were collected using Leginon (Suloway et al., 2005) with a total electron dose of 50.44 e-/Å^2.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
</entry>